Processor Configuration Registers
2.19.39 LCTL—Link Control Register
This register allows control of PCI Express link.
B/D/F/Type: 0/6/0/PCI
Address Offset: B0–B1h
Reset Value: 0000h
Access: RW, RO, RW-SC
Bit Attr
Reset
Value
Description
15:12 RO 0000b Reserved
11 RW 0b
Link Autonomous Bandwidth Interrupt Enable (LABIE)
When Set, this bit enables the generation of an interrupt to indicate that the
Link Autonomous Bandwidth Status bit has been Set.
This bit is not applicable and is reserved for Endpoint devices, PCI Express to
PCI/PCI-X bridges, and Upstream Ports of Switches.
Devices that do not implement the Link Bandwidth Notification capability
must hardwire this bit to 0b.
10 RW 0b
Link Bandwidth Management Interrupt Enable (LBMIE)
When Set, this bit enables the generation of an interrupt to indicate that the
Link Bandwidth Management Status bit has been Set.
This bit is not applicable and is reserved for Endpoint devices, PCI Express to
PCI/PCI-X bridges, and Upstream Ports of Switches.
9RW 0b
Hardware Autonomous Width Disable (HAWD)
When Set, this bit disables hardware from changing the Link width for
reasons other than attempting to correct unreliable Link operation by
reducing Link width.
Devices that do not implement the ability autonomously to change Link width
are permitted to hardwire this bit to 0b.
8RO 0b
Enable Clock Power Management (ECPM)
Applicable only for form factors that support a "Clock Request" (CLKREQ#)
mechanism, this enable functions as follows
0 = Clock power management is disabled and device must hold CLKREQ#
signal low
1 = When this bit is set to 1 the device is permitted to use CLKREQ# signal
to power manage link clock according to protocol defined in appropriate
form factor specification.
Components that do not support Clock Power Management (as indicated by a
0b value in the Clock Power Management bit of the Link Capabilities Register)
must hardwire this bit to 0b.
7RW 0b
Extended Synch (ES)
0 = Standard Fast Training Sequence (FTS).
1 = Forces the transmission of additional ordered sets when exiting the L0s
state and when in the Recovery state.
This mode provides external devices (such as, logic analyzers) monitoring
the Link time to achieve bit and symbol lock before the link enters L0 and
resumes communication.
This is a test mode only and may cause other undesired side effects such as
buffer overflows or underruns.
6RW 0b
Common Clock Configuration (CCC)
0 = Indicates that this component and the component at the opposite end of
this Link are operating with asynchronous reference clock.
1 = Indicates that this component and the component at the opposite end of
this Link are operating with a distributed common reference clock.
The state of this bit affects the L0s Exit Latency reported in LCAP[14:12] and
the N_FTS value advertised during link training.
See PEGL0SLAT at offset 22Ch.