Intel B940 Datasheet Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 360
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
Processor Configuration Registers
100 Datasheet, Volume 2
2.8.47 TIS1—Thermal Interrupt Status 1 Register
This register is used to report which specific error condition resulted in the D2F0 or
D2F1 ERRSTS[Thermal Sensor event for SMI/SCI/SERR] or memory mapped IIR
Thermal Event. Software can examine the current state of the thermal zones by
examining the TSS. Software can distinguish internal or external Trip Event by
examining TSS.
B/D/F/Type: 0/0/0/MCHBAR
Address Offset: 101E–101Fh
Reset Value: 0000h
Access: RO, RW1C
Bit Attr
Reset
Value
Description
15:14 RO 00b Reserved
13 RW1C 0b
Was Catastrophic Thermal Sensor Interrupt Event (WCTSIE)
1 = Indicates that a Catastrophic Thermal Sensor trip based on a higher to
lower temperature transition thru the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
12 RW1C 0b
Was Hot Thermal Sensor Interrupt Event (WHTSIE)
1 = A Hot Thermal Sensor trip occurred based on a higher to lower
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
11 RW1C 0b
Was Aux 3 Thermal Sensor Interrupt Event (WA3TSIE)
1 = Aux 3 Thermal Sensor trip occurred based on a higher to lower
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
10 RW1C 0b
Was Aux 2 Thermal Sensor Interrupt Event (WA2TSIE)
1 = Aux 2 Thermal Sensor trip occurred based on a higher to lower
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
9RW1C 0b
Was Aux 1 Thermal Sensor Interrupt Event (WA1TSIE)
1 = Aux 1 Thermal Sensor trip occurred based on a higher to lower
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
8RW1C 0b
Was Aux 0 Thermal Sensor Interrupt Event (WA0TSIE)
1 = Aux 0 Thermal Sensor trip occurred based on a higher to lower
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
7:6 RO 00b Reserved
5RW1C 0b
Catastrophic Thermal Sensor Interrupt Event (CTSIE)
1 = A Catastrophic Thermal Sensor trip event occurred based on a lower to
higher temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.
4RW1C 0b
Hot Thermal Sensor Interrupt Event (HTSIE)
1 = A Hot Thermal Sensor trip event occurred based on a lower to higher
temperature transition through the trip point.
0 = No trip for this event.
Software must write a 1 to clear this status bit.