Intel B940 Datasheet Page 141

  • Download
  • Add to my manuals
  • Print
  • Page
    / 360
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 140
Datasheet, Volume 2 141
Processor Configuration Registers
2.10.38 DSTS—Device Status Register
This register reflects status corresponding to controls in the Device Control register.
The error reporting bits are in reference to errors detected by this device, not errors
messages received across the link.
B/D/F/Type: 0/1/0/PCI
Address Offset: AA–ABh
Reset Value: 0000h
Access: RO, RW1C
Bit Attr
Reset
Value
Description
15:6 RO 000h
Reserved and Zero: Reserved for future R/WC/S implementations; software
must use 0 for writes to bits.
5RO 0b
Transactions Pending (TP)
0 = All pending transactions (including completions for any outstanding non-
posted requests on any used virtual channel) have been completed.
1 = Indicates that the device has transaction(s) pending (including
completions for any outstanding non-posted requests for all used Traffic
Classes).
4RO 0bReserved
3RW1C 0b
Unsupported Request Detected (URD)
When set, this bit indicates that the Device received an Unsupported
Request. Errors are logged in this register regardless of whether error
reporting is enabled or not in the Device Control Register.
Additionally, the Non-Fatal Error Detected bit or the Fatal Error Detected bit is
set according to the setting of the Unsupported Request Error Severity bit. In
production systems setting the Fatal Error Detected bit is not an option as
support for AER will not be reported.
2RW1C 0b
Fatal Error Detected (FED)
When set, this bit indicates that fatal error(s) were detected. Errors are
logged in this register regardless of whether error reporting is enabled or not
in the Device Control register. When Advanced Error Handling is enabled,
errors are logged in this register regardless of the settings of the
uncorrectable error mask register.
1RW1C 0b
Non-Fatal Error Detected (NFED)
When set, this bit indicates that non-fatal error(s) were detected. Errors are
logged in this register regardless of whether error reporting is enabled or not
in the Device Control register. When Advanced Error Handling is enabled,
errors are logged in this register regardless of the settings of the
uncorrectable error mask register.
0RW1C 0b
Correctable Error Detected (CED)
When set, this bit indicates that correctable error(s) were detected. Errors
are logged in this register regardless of whether error reporting is enabled or
not in the Device Control register.
When Advanced Error Handling is enabled, errors are logged in this register
regardless of the settings of the correctable error mask register.
Page view 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 359 360

Comments to this Manuals