7-52 Vol. 3A
MULTIPLE-PROCESSOR MANAGEMENT
other logical processors in the physical package. For this reason, halting idle logical processors
optimizes the performance.
5
If all logical processors within a physical package are halted, the
processor will enter a power-saving state.
7.11.6.4 Potential Usage of MONITOR/MWAIT in C1 Idle Loops
An operating system may also consider replacing HLT with MONITOR/MWAIT in its C1 idle
loop. An example is shown in Example 7-7:
Example 7-7 An OS Idle Loop with MONITOR/MWAIT in the C1 Idle Loop
// WorkQueue is a memory location indicating there is a thread
// ready to run. A non-zero value for WorkQueue is assumed to
// indicate the presence of work to be scheduled on the processor.
// The following example assumes that the necessary padding has been
// added surrounding WorkQueue to eliminate false wakeups
// The idle loop is entered with interrupts disabled.
WHILE (1) {
IF (WorkQueue) THEN {
// Schedule work at WorkQueue
} ELSE {
// No work to do - wait in appropriate C-state handler depending
// on Idle time accumulated
IF (IdleTime >= IdleTimeThreshhold) THEN {
// Call appropriate C1, C2, C3 state handler, C1
// handler shown below
}
}
}
// C1 handler uses a Halt instruction
VOID C1Handler()
{
MONITOR WorkQueue // Setup of eax with WorkQueue LinearAddress,
// ECX, EDX = 0
IF (WorkQueue != 0) THEN {
STI
MWAIT // EAX, ECX = 0
}
}
5. Excessive transitions into and out of the HALT state could also incur performance penalties. Operating
systems should evaluate the performance trade-offs for their operating system.