11-10 Intel® PXA26x Processor Family Developer’s Manual
Fast Infrared Communication Port
11.3.2 FICP Control Register 1
FICP control register 1 (ICCR1) contains the 8-bit address match value field that the FICP uses to
selectively receive frames. To allow the address match value to be changed during active receive
operation, ICCR1 may be written while the FICP is enabled.
3TXE
TRANSMIT ENABLE:
0 – FICP transmit logic disabled.
1 – FICP transmit logic enabled if ICCR0[ITR] is set.
All other control bits must be configured before TXE is set. An SIP is transmitted
immediately after the transmitter is enabled. If the transmit FIFO is empty, preambles are
sent until data is placed in the FIFO.
If TXE is cleared while it transmits data, transmission stops immediately, all data in the
transmit FIFO and serial output shifter is cleared, and the SIU takes control of the transmit
data pin.
While communication is normally half-duplex, it is possible to transmit and receive data at
the same time. Duplex communication is used for testing in Loopback Mode.
If TXE is used to clear the transmitter, check ICSR1[TBY] to ensure the transmitter is not
busy before the transmitter is re-enabled.
2TUS
TRANSMIT FIFO UNDERRUN SELECT:
A transmit FIFO underrun can either end the current frame normally, or transmit an abort.
0 Transmit FIFO underrun causes CRC, stop flag, and SIP to be transmitted, and masks
transmit underrun interrupt generation.
1 – Transmit FIFO underrun causes abort to be transmitted, and generates an interrupt.
Clearing ICCR0[TUS] does not affect the current state of ICSR0[TUR] or prevent TUR from
being set or cleared by the transmit FIFO. After an abort, a SIP is transmitted followed by
16 preambles. Preambles continue until data is in the FIFO.
1LBM
LOOPBACK MODE:
Used for testing FICP.
0 – Normal FICP operation enabled.
1 – Output of transmit serial shifter is connected to input of receive serial shifter.
0ITR
IrDA TRANSMISSION:
0 – ICP unit is not enabled.
1 – ICP unit is enabled.
Table 11-2. Fast Infrared Communication Port Control Register 0 (Sheet 2 of 2)
0x4080 0000
Fast Infrared Communication Port
Control Register 0 (ICCR0)
FICP
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
AME
TIE
RIE
RXE
TXE
TUS
LBM
ITR
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Bits Name Description