Intel® PXA26x Processor Family Developer’s Manual 15-25
MultiMediaCard Controller
15.5.5 MMC_CMDAT Register
The MMC_CMDAT register controls the command sequence. Writing to this register starts the
command sequence on the MMC bus when the MMC bus clock is turned on.
1CRC_ON
CRC GENERATION ENABLE:
0 – Disables CRC generation and verification
1 – Enables CRC generation and verification
0SPI_EN
SPI MODE ENABLE:
0 – Disables SPI mode
1 – Enables SPI mode
Table 15-9. MMC_SPI Register (Sheet 2 of 2)
Physical Address
4110_000c
MMC_SPI Register MMC
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
SPI_CS_ADDRESS
SPI_CS_EN
CRC_ON
SPI_EN
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Bits Name Description
Table 15-10. MMC_CMDAT Register (Sheet 1 of 2)
Physical Address
4110_0010
MMC_CMDAT Register MMC
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
MMC_DMA_EN
INIT
BUSY
STREAM_BLOCK
WRITE/READ
DATA_EN
RESPONSE_FORMAT[1:0]
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0
Bits Name Description
31:8 Reserved
7
MMC_DMA_E
N
DMA MODE ENABLE:
0 – Program I/O mode
1 – DMA mode
When DMA mode is used, this bit is a mask on RXFIFO_RD_REQ and TXFIFO_WR_REQ
interrupts.
6INIT
80 INITIALIZATION CLOCKS:
0 – Do not precede command sequence with 80 clocks
1 – Precede command sequence with 80 clocks