9.4.1 Grounding
The output ground of the pins of the power supply provides the output power return path. The
output connector ground pins are connected to the safety ground (power supply enclosure).
9.4.2 Stand-by Outputs
The 5 VSB output should be present when an AC input is greater than the power supply turn-on
voltage is applied.
9.4.3 Remote Sense
The power supply should have remote sense return (ReturnS) to regulate out ground drops for
all output voltages: +3.3 V, +5 V, +12 V1, +12 V2, +12 V3, +12 V4, -12 V, and 5 VSB. The
power supply should use remote sense to regulate out drops in the system for the +3.3 V, +5 V,
and +12 V1 outputs.
The +12 V1, +12 V2, +12 V3, +12 V4, –12 V, and 5V SB outputs only use remote sense
referenced to the ReturnS signal. The remote sense input impedance to the power supply must
be greater than 200 on 3.3 VS and 5 VS. This is the value of the resistor connecting the
remote sense to the output voltage internal to the power supply.
Remote sense must be able to regulate out a minimum of 200 mV drop. The remote sense
return (ReturnS) must be able to regulate out a minimum of 20 0mV drop in the power ground
return. The current in any remote sense line should be less than 5 mA to prevent voltage
sensing errors.
The power supply must operate within specification over the full range of voltage drops from the
power supply’s output connector to the remote sense points.