Intel® Server Boards S5520HC and S5500HCV TPS Design and Environmental Specifications
Revision 1.2
Intel order number E39529-009
127
9. Design and Environmental Specifications
9.1 Intel
®
Server Boards S5520HC and S5500HCV Design
Specifications
Operation of the Intel
®
Server Boards S5520HC and/or S5500HCV at conditions beyond those
shown in the following table may cause permanent damage to the system. Exposure to absolute
maximum rating conditions for extended periods may affect system reliability.
Table 70. Server Board Design Specifications
Operating Temperature
0º C to 55º C 1 (32º F to 131º F)
Non-Operating Temperature
-40º C to 70º C (-40º F to 158º F)
DC Voltage
± 5% of all nominal voltages
Shock (Unpackaged)
Trapezoidal, 50 G, 170 inches / sec
Shock (Packaged)
< 20 pounds
20 to < 40 pounds
40 to < 80 pounds
80 to < 100 pounds
100 to < 120 pounds
120 pounds
36 inches
30 inches
24 inches
18 inches
12 inches
9 inches
Vibration (Unpackaged)
5 Hz to 500 Hz 3.13 g RMS random
Note:
1
Chassis design must provide proper airflow to avoid exceeding the processor maximum case
temperature.
Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and
power delivery components that need adequate airflow to cool. Intel ensures through its own
chassis development and testing that when Intel
®
server building blocks are used together, the
fully integrated system will meet the intended thermal requirements of these components. It is
the responsibility of the system integrator who chooses not to use Intel
®
developed server
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of its published operating or non-operating limits.
9.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 30 C (ambient air). These
values are derived using a historical failure rate and multiplied by factors for application,
electrical and/or thermal stress and for device maturity. You should view MTBF estimates as
“reference numbers” only.
Calculation Model: Telcordia Issue 1, method I case 3
Operating Temperature: Server in 30° C ambient air