Intel S5500HCVR Datasheet Page 171

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 170
Intel® Server Board S5520HC / S5500HCV TPS Appendix C: BMC Sensor Tables
Revision 1.2
Intel order number E39529-009
157
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
Fan Tachometer Sensors
(Chassis specific
sensor names)
30h–39h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog R, T M
Fan Present Sensors
(Fan x Present)
40h–45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Triggered
Offset
Auto
00 - Fully
redundant
OK
01 –
Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded
Fan Redundancy
1
(Fan Redundancy)
46h
Chassis-
specific
Fan
04h
Generic
0Bh
04 - Non-
redundant:
Sufficient
resources.
Transition from
insufficient.
Degraded
As and
De
– Trig Offset A