Intel S1200BTSR Datasheet Page 125

  • Download
  • Add to my manuals
  • Print
  • Page
    / 153
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 124
Intel® Server Board S1200BT TPS Design and Environmental Specifications
Revision 1.0
Intel order number G13326-003
113
10.3.1 Grounding
The grounds of the power supply output connector pins provide the power return path. The
output connector ground pins are connected to the safety ground (power supply enclosure).
This grounding is designed to ensure passing the maximum allowed common mode
noise levels.
The power supply is provided with a reliable protective earth ground. All secondary circuits are
connected to protective earth ground. Resistance of the ground returns to chassis does not
exceed 1.0 m. This path may be used to carry DC current.
10.3.2 Standby Outputs
The 5 VSB output is present when an AC input greater than the power supply turn on voltage
is applied.
10.3.3 Remote Sense
The power supply has remote sense return (ReturnS) to regulate out ground drops for all output
voltages: +3.3 V, +5 V, +12 V, -12 V, and 5 VSB. The power supply uses remote sense to
regulate out drops in the system for the +3.3 V, +5 V, and 12 V outputs. The power supply must
operate within specification over the full range of voltage drops from the power supply‘s output
connector to the remote sense points.
10.3.4 Voltage Regulation
The power supply output voltages must stay within the following voltage limits when operating
at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
All outputs are measured with reference to the return remote sense signal (ReturnS).
Table 48. Voltage Regulation Limits
Parameter
Tolerance
Minimum
Normal
Maximum
Units
+ 3.3 V
- 5% / +5%
+3.14
+3.30
+3.46
Vrms
+ 5 V
- 5% / +5%
+4.75
+5.00
+5.25
Vrms
+ 12 V
- 5% / +5%
+11.40
+12.00
+12.60
Vrms
- 12 V
- 10% / +10%
-13.20
-12.00
-10.80
Vrms
+ 5 VSB
- 5% / +5%
+4.75
+5.00
+5.25
Vrms
10.3.5 Dynamic Loading
The output voltages remain within limits for the step loading and capacitive loading specified in
the following table. The load transient repetition rate is tested between 50 Hz and 5 kHz at duty
cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The
step load may occur anywhere within the Min load to the Max load conditions.
Table 49. Transient Load Requirements
Output
Step Load Size
(See note 2)
Load Slew Rate
Test capacitive Load
+3.3 V
5.0 A
0.25 A/µsec
250 µF
+5 V
6.0 A
0.25 A/µsec
400 µF
12 V
11.0 A
0.25 A/µsec
500 µF
Page view 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 152 153

Comments to this Manuals

Chrisbenty 04 May 2024 | 04:26:23

Hello, im noob :)