Intel B80532PG0962M Datasheet Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
84 Intel
®
Pentium
®
4 Processor on 0.13 Micron Process Datasheet
Boxed Processor Specifications
NOTE:
1. Set point variance is approximately ± 1 °C from fan heatsink to fan heatsink.
Table 7-2. Boxed Processor Fan Heatsink Set Points
Boxed Processor Fan
Heatsink Set Point (ºC)
Boxed Processor Fan Speed Notes
Boxed Intel
®
Pentium
®
4 Processors 2.80 GHz (and below)
X 33
When the internal chassis temperature is below or equal to this set point,
the fan operates at its lowest speed. Recommended maximum internal
chassis temperature for nominal operating environment.
1
Y = 40
When the internal chassis temperature is at this point, the fan operates
between its lowest and highest speeds. Recommended maximum internal
chassis temperature for worst-case operating environment.
Z
43
When the internal chassis temperature is above or equal to this set point,
the fan operates at its highest speed.
1
Boxed Intel
®
Pentium
®
4 Processors 3 GHz (and above)
X 32
When the internal chassis temperature is below or equal to this set point,
the fan operates at its lowest speed. Recommended maximum internal
chassis temperature for nominal operating environment.
1
Y = 38
When the internal chassis temperature is at this point, the fan operates
between its lowest and highest speeds. Recommended maximum internal
chassis temperature for worst-case operating environment.
Z
40
When the internal chassis temperature is above or equal to this set point,
the fan operates at its highest speed.
1
Page view 83
1 2 ... 79 80 81 82 83 84 85

Comments to this Manuals