Environmental Limits Specification Intel
®
Server Board S2400GP TPS
Revision 1.01
Intel order number G50295-002
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
11.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 30 degree C (ambient air).
These values are derived using a historical failure rate and multiplied by factors for application,
electrical and/or thermal stress and for device maturity. You should view MTBF estimates as
“reference numbers” only.
Calculate standard: Telcordia* issue 2
Calculate Method: Method I-D
Temperature = 40 degree C
Environment = GB, GC – Ground Benign, Controlled
Model = Serial
Duty cycle = 100%
Component Quality: Level II
Adhere to De-rating data
Table 49. MTBF Estimate
Intel
®
Server Board
S2400GP
11.3 Server Board Power Distribution
This section provides power supply design guidelines for a system using the Intel
®
Server Board
S2400GP. The following diagram shows the power distribution implemented on this server
board. For power supply data, please refer to the chapter that describes the power system
options including 460W, 550W, 750W or 1200W power supply. Please note the intent of
460W/550W/750W/1200W power supply data is to provide customers with a guide to assist in
defining and/or selecting a power supply for custom server platform designs that utilize the
server boards detailed in this document.