Page view 52
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.0 45
Intel order number G17455-004
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
Power Supply 1
+12V % of Maximum
Current Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 2
+12V % of Maximum
Current Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Processor Status
(P1 Status)
70h All
Processor
07h
Sensor Specific
6Fh
01 - Thermal trip Fatal
As and
De
Trig
Offset
M X
07 - Presence OK
Processor Thermal
Margin
(P1 Therm Margin)
74h All
Temperature
01h
Threshold
01h
– – Analog R, T A
Processor Thermal
Control %
(P1 Therm Ctrl %)
78h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
Trig
Offset
A –
Catastrophic Error
(CATERR)
80h All
Processor
07h
Digital Discrete
03h
01 – State Asserted Non-fatal
As and
De
Trig
Offset
M –