Intel R1304BTSSFAN Datasheet Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 67
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS 350W Power Subsystem
Revision 2.0 23
Intel order number G17455-004
Table 23. Over Load Protection (OCP) Limits
Output Voltage Continuous Load
Current Limit MIN Current Limit MAX
+12V1
18.2A 20A
+12V2
18.2A 20A
+5V
19.2A 24A
+3.3V
12A 15A
-12V
4A
+5VSB
4.5A
4.8.2 Over Voltage Protection (OVP)
Each output shall have individual OVP protection circuits built in and it shall be locally sensed.
The PSU shall shutdown and latch off after an over voltage condition occurs. The output
voltages are measured at the harness connectors. The voltage shall never exceed the
maximum levels when measured at the power pins of the output harness connector during any
single point of fail.
The voltage shall never trip any lower than the minimum levels when
measured at the power pins of the connector.
Table 24. Over Voltage Protection (OVP) Limits
Output Voltage OVP MIN (V) OVP MAX (V)
+3.3V
3.7 4.5
+5V
5.7 6.5
+12V1/+12V2
13.3 15.6
-12V
-13.3 -15.6
+5VSB
5.7 6.5
4.8.3 Over Temperature Protection (OTP)
The power supply shall be protected against over temperature conditions caused by loss of fan
cooling or excessive ambient temperature. In an OTP condition the PSU will shut down. When
the power supply temperature drops to within specified limits, the power supply shall restore
power automatically, while the +5VSB remains always on. The OTP trip level shall have a
minimum of 4°C of ambient temperature hysteresis, so that the power supply will not oscillate
on and off due to temperature recovery condition.
4.9 PMBus
The PMBus features included in this specification are requirements for ac/dc silver box power
supply for use in server systems. This specification is based on the PMBus™ Specifications
Parts I and II, revision 1.1X3.
4.9.1 Related Documents
PMBus™ Power System Management Protocol Specification Part I – General Requirements,
Transport And Electrical Interface; Revision 1.1X3
PMBus™ Power System Management Protocol Specification Part II – Command Language;
Revision 1.1X3 SMBus 2.0.