Intel AT80612002931AB Datasheet Page 396

  • Download
  • Add to my manuals
  • Print
  • Page
    / 520
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 395
Reliability, Availability, Serviceability (RAS)
Intel
®
Xeon
®
Processor C5500/C3500 Series
Datasheet, Volume 1 February 2010
396 Order Number: 323103-001
20
IIO Configuration
Register Parity
Error
(not including
Intel
®
QPI, PCIe
or DMA registers
which are covered
elsewhere)
2
No Response. This error is not
associated with a cycle. IIO
detects and logs the error.
FERR/NERR is logged in Miscellaneous and Global
Fatal Error Log Registers:
MIFFERRST
MIFNERRST
GFERRST
GFFERRST
GFFERRTIME
GFNERRST
No header is logged.
21
Persistent SMBus
retry failure.
2
No Response. This error is not
associated with a cycle. IIO
detects and logs the error.
FERR/NERR is logged in Miscellaneous and Global
Fatal Error Log Registers:
MIFFERRST
MIFFERRHD
MIFNERRST
GFERRST
GFFERRST
GFFERRTIME
GFNERRST
No header is logged for this error.
22 Reserved
23
Virtual Pin Port
Error.
(IIO encountered
persistent VPP
failure. The VPP is
unable to
operate.)
Table 129. IIO Error Summary (Sheet 3 of 15)
ID Error
Default
Error
Severity
Transaction Response Default Error Logging
1
Page view 395
1 2 ... 391 392 393 394 395 396 397 398 399 400 401 ... 519 520

Comments to this Manuals

No comments