Environmental Limits Intel® Entry Server Chassis SC5250-E
Revision 1.02
Intel order number C32881-001
54
11. Environmental Limits
11.1 System Office Environment
Table 11. System Office Environment Summary
Parameter Limits
Operating Temperature +5oC to +35oC with the maximum rate of change not to exceed 10oC per hour.
Non-Operating Temperature -40oC to +70oC
Non-Operating Humidity 95%, non-condensing @ 30oC
Acoustic noise 50 dBA in a typical office ambient temperature (18-25C)
Operating Shock No errors with a half sine wave shock of 2G (with 11-millisecond duration).
Package Shock Operational after a free fall, 18 – 24 inch depending on the weight.
ESD 15kV per Intel Environmental Test Specification
11.2 System Environmental Testing
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-05.
These tests shall include:
• Temperature Operating and Non-Operating
• Humidity Non-Operating
• Packaged Shock
• Packaged and Unpackaged Vibration
• AC Voltage, Frequency, and Source Interrupt
• AC Surge
• Acoustics
• Electrostatic Discharge (ESD)
• EMC Radiated Investigation
Comments to this Manuals