Intel® Entry Server Chassis SC5250-E System Peripheral Bays
Revision 1.02
Intel order number C32881-001
37
Host Side Drive 3 J4A1
This connector is
shared for both Drive 2
and Drive 3. Drive 3 is
the one closest to the
PCB.
LED Connector J4R1
This connector is only
used with the Intel®
Raid Controller
SRCS14L and is used
to drive the activity
LED’s.
7.6.2 SATA Hot-swap Backplane Specifications
The Server Chassis SC5200 and SC5250-E hot-swap SATA backplane is an embedded
application subsystem, which during normal operation does the following:
Responds to SATA messages (transmitted to the backplane via the SATA bus).
The Server Chassis SC5200 and SC5250-E hot-swap SATA backplane board set is made up of
the following functional blocks:
SATA interface with SATA drive connectors
SATA drive power control
Fault indicator support (only supported when a RAID Controller SRCS14L is installed)
7.7 Front Panel
The front panel control buttons and LED indicators are displayed in Error! Reference source
not found.. Not shown (in the figure below) is a tool-activated non-maskable Interrupt (NMI)
switch located below the Status LED. Server chassis SC5250-E provides a 34-pin cable option
with the chassis kit. A 34-pin Entry Ebay SSI (rev 3.0) front panel header for Intel boards is
located on the back of the front panel. This allows for a 34-pin ribbon cable connection for use
with SSI rev 3.0-compliant server boards. The connector cable is compatible with the 24-pin SSI
standard.
When the hot-swap drive bay is installed, a bi-color hard drive LED is located on each drive
carrier (five total) to indicate specific drive failure or activity. For pedestal systems, these LEDs
are visible upon opening the front bezel door.