Getting Started
RAID Array 410 for Windows NT – Intel
Installation Guide
Order Number: EK–SMRAC-IG. C01
Digital Equipment Corporation
Maynard, Massachusetts
Page view 0
1 2 3 4 5 6 ... 59 60

Summary of Contents

Page 1 - Getting Started

Getting StartedRAID Array 410 for Windows NT – IntelInstallation GuideOrder Number: EK–SMRAC-IG. C01Digital Equipment CorporationMaynard, Massachuset

Page 2

Getting Started - RAID Array 410 for Windows NT – Intelx EK–SMRAC-IG. C01Installation “Checklist”This section expands upon the preceding steps to prov

Page 3 - Contents

Getting StartedEK–SMRAC-IG. C01 xiVerify User-Supplied Hardware and Software (System Requirements)The StorageWorks RAID Array 410 Subsystem requires t

Page 5 - Revision Record

EK–SMRAC–IG. C01 1–11Unpacking and Setting Up Your RAID Array 410Subsystem ComponentsThis chapter describes the site preparation and unpacking procedu

Page 6

Getting Started - RAID Array 410 for Windows NT – Intel1–2 EK–SMRAC–IG. C011.2 Unpacking the RAID Array 410 (SWXRA-Yx)The RAID Array 410 is packed in

Page 7 - About This Guide

Chapter 1. Unpacking and Setting Up Your RAID Array 410 Subsystem ComponentsEK–SMRAC–IG. C01 1–3Figure 1–2 Unpacking the RAID Array 410Figure 1–3 In

Page 8 - Conventions

Getting Started - RAID Array 410 for Windows NT – Intel1–4 EK–SMRAC–IG. C013. Grasping the sheet metal base assembly, carefully lift the rear of the R

Page 9

Chapter 1. Unpacking and Setting Up Your RAID Array 410 Subsystem ComponentsEK–SMRAC–IG. C01 1–5 Follow these electrostatic discharge (ESD) precaution

Page 10 - Perform a System Backup

Getting Started - RAID Array 410 for Windows NT – Intel1–6 EK–SMRAC–IG. C013. Replace the ESD shield over the PC (program) card. To do so, first ensur

Page 11

Chapter 1. Unpacking and Setting Up Your RAID Array 410 Subsystem ComponentsEK–SMRAC–IG. C01 1–7To install an SBB, hold it in both hands, insert it in

Page 12

Third Edition, June 1996The disclosure of this information does not grant to the user a license under any patents, pendingpatents, trademarks, or copy

Page 13 - Subsystem Components

Getting Started - RAID Array 410 for Windows NT – Intel1–8 EK–SMRAC–IG. C013. Apply power to the controller, by using the power switch on the AC Power

Page 14 - 1–2 EK–SMRAC–IG. C01

Chapter 1. Unpacking and Setting Up Your RAID Array 410 Subsystem ComponentsEK–SMRAC–IG. C01 1–9Figure 1–6 SWXSC-AA Components (Cabinet removed for c

Page 16 - 1–4 EK–SMRAC–IG. C01

EK–SMRAC–IG. C01 2–12Host Adapter Installation –Intel-based SystemIn preparing your array for first time use, you need to connect your Intel-based sys

Page 17 - EK–SMRAC–IG. C01 1–5

Getting Started - RAID Array 410 for Windows NT – Intel2–2 EK–SMRAC–IG. C01You need the following before you begin:• The appropriate host adapter (SW

Page 18 - 1–6 EK–SMRAC–IG. C01

Chapter 2. Host Adapter Installation – Intel-Based SystemEK–SMRAC–IG. C01 2–3Connect the SCSI cable to the host adapter as shown in Figure 3–1.3. The

Page 19 - EK–SMRAC–IG. C01 1–7

Getting Started - RAID Array 410 for Windows NT – Intel2–4 EK–SMRAC–IG. C01Secure the SCSI cable to the trilink on the controller by tightening the tw

Page 20 - 1–8 EK–SMRAC–IG. C01

Chapter 2. Host Adapter Installation – Intel-Based SystemEK–SMRAC–IG. C01 2–54. Connect the power cable to the storage enclosure if it has not yet bee

Page 21 - EK–SMRAC–IG. C01 1–9

Getting Started - RAID Array 410 for Windows NT – Intel2–6 EK–SMRAC–IG. C01After Windows NT is installed, replace the device driver and install the de

Page 22

Chapter 2. Host Adapter Installation – Intel-Based SystemEK–SMRAC–IG. C01 2–7 where: “drive_letter” and “NT_root_directory” correspond to the root pat

Page 23 - Intel-based System

EK–SMRAC–IG. C01 iiiContentsRevision Record ...vAbo

Page 25 - 2.2 Installing the Subsystem

EK–SMRAC–IG. C01 3–13Installing and Using the RAID Manager forWindows NTThis chapter contains instructions for installing the RAID Manager software, c

Page 26 - 2–4 EK–SMRAC–IG. C01

Getting Started - RAID Array 410 for Windows NT – Intel3–2 EK–SMRAC–IG. C01• Identify the controller as Model SWXRC-04.• Set up your initial RAID co

Page 27 - 2.3 Configuration Utilities

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–3Figure 3−−2 The System ID Window4. At the RAID Manager

Page 28

Getting Started - RAID Array 410 for Windows NT – Intel3–4 EK–SMRAC–IG. C01Select the choice, “D” for Host Functionality; this sets the controller to

Page 29 - Congratulations!

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–5To help you get started, and to familiarize you with the

Page 30

Getting Started - RAID Array 410 for Windows NT – Intel3–6 EK–SMRAC–IG. C013. Return to the main window and again click on the Settings pull-down menu

Page 31 - Windows NT

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–7Figure 3–5 Updated Physical View3.6.2 Practice Example:

Page 32

Getting Started - RAID Array 410 for Windows NT – Intel3–8 EK–SMRAC–IG. C012. For this example, select Single Disk - JBOD and choose a target ID (by d

Page 33

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–9The RAID Manager responds by displaying a message window

Page 34 - 3–4 EK–SMRAC–IG. C01

Getting Started - RAID Array 410 for Windows NT – Inteliv EK–SMRAC–IG. B013.7 Saving the RAID Configuration ...

Page 35 - EK–SMRAC–IG. C01 3–5

Getting Started - RAID Array 410 for Windows NT – Intel3–10 EK–SMRAC–IG. C012. For this example, select RAID 1 - Mirrorset, then, in the Set Name box,

Page 36

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–112. Choose (click on) Spare from the choices listed, the

Page 37

Getting Started - RAID Array 410 for Windows NT – Intel3–12 EK–SMRAC–IG. C01NOTEAfter saving (or recording) your configuration, you must rebootyour sy

Page 38

Chapter 3. Installing and Using the RAID Array 410 Manager for Windows NTEK–SMRAC–IG. C01 3–13Record the information in the following table:Date_____

Page 40

EK–SMRAC–IG. C01 4–14Completing your Configuration Setup underWindows NTThis chapter contains instructions for how to complete your configuration set

Page 41

Chapter 4. Completing Your Configuration Setup Under Windows NT4–2 EK–SMRAC–IG. C01If an entry for hszdisk appears with a 1 in the Event column, simil

Page 42 - Chapter 4, Completing your

Getting Started - RAID Array 410 for Windows NT – IntelEK–SMRAC–IG. C01 4–3NOTEThe first time you run Disk Administrator after adding new disks,one or

Page 43 - Disk(s) Used

Chapter 4. Completing Your Configuration Setup Under Windows NT4–4 EK–SMRAC–IG. C01The figure also shows the corresponding free space for each entity.

Page 44

Getting Started - RAID Array 410 for Windows NT – IntelEK–SMRAC–IG. C01 4–5Figure 4–4 Partition Pull-Down MenuSee Figure 4–5 Create Primary Partitio

Page 45

EK–SMRAC–IG. C01 vRevision RecordThis Revision Record provides a concise publication history of this manual. It lists the manualrevision levels, relea

Page 46

Chapter 4. Completing Your Configuration Setup Under Windows NT4–6 EK–SMRAC–IG. C01You may, however, make these assignments “permanent.” (For more inf

Page 47 - EK–SMRAC–IG. C01 4–3

Getting Started - RAID Array 410 for Windows NT – IntelEK–SMRAC–IG. C01 4–7Figure 4–7 Format Menu6. Continue to format each new partition until all p

Page 48 - Create (see Figure 4–4)

Chapter 4. Completing Your Configuration Setup Under Windows NT4–8 EK–SMRAC–IG. C017. You now need to reboot your system for changes made thus far to

Page 49 - OK. (Depending upon

EK–SMRAC–IG. C01 A–1AConfiguration Records – Blank FormsThis contains copies of the table used in Chapter 3 to record the configuration of your system

Page 50

Getting Started – RAID Array 410 for Windows NT – IntelA–2 EK–SMRAC–IG. C01Date__________________Name of RAIDset Type of RAIDset Target LUNDisk(s) Use

Page 51 - Figure 4–7 Format Menu

Appendix A. Configuration Records – Blank FormsEK–SMRAC–IG. C01 A–3Date__________________Name of RAIDset Type of RAIDset Target LUNDisk(s) Used

Page 52 - 4–8 EK–SMRAC–IG. C01

Getting Started – RAID Array 410 for Windows NT – IntelA–4 EK–SMRAC–IG. C01Date__________________Name of RAIDset Type of RAIDset Target LUNDisk(s) Use

Page 53 - EK–SMRAC–IG. C01 A–1

EK–SMRAC-IG. C01 B–1BAccessing the Command Line Interpreter (CLI)This chapter contains instructions for accessing the Command Line Interpreter (CLI).

Page 54 - A–2 EK–SMRAC–IG. C01

Getting Started – RAID Array 410 for Windows NT –IntelB–2 EK–SMRAC-IG. C013. Set the communications parameters to:• • 9600 baud• • 8 bits• • 1 sto

Page 55 - EK–SMRAC–IG. C01 A–3

Reader’s CommentsManual Order Number:EK–SMRAC–IG. C01 Digital is committed to providing the best possible products

Page 58 - • • No parity

EK–SMRAC–IG. C01 viiAbout This GuideThis section identifies the audience of this guide and describes the contents (chapter by chapter) and structure.I

Page 59 - Reader’s Comments

Getting Started - RAID Array 410 for Windows NT – IntelEK–SMRAC–IG. B01viiiAppendix A: Configuration RecordThis appendix contains blank forms that ma

Page 60

EK–SMRAC-IG. C01 ixGetting StartedThis section provides an overview for preparing and installing the RAID Array 410 for Windows NT in your Intel-based