Intel SRCU41L User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Intel
®
Raid Controller SRCU41L User Manual 15
Storage Adapter Characteristics
3.1.2 Decoding the Audible Alarm
The following beep codes are used on Intel RAID controllers that use software stack 2. Thesecodes
usually indicate a drive has failed:
Degraded Array: Short tone, one second on, one second off
Failed Array: Long tone, three seconds on, one second off
Hot Spare Commissioned: Short tone, one second on, three seconds off
These drive failure tones will repeat until the problem is corrected or until the alarm issilenced or
disabled.
A tone alarm will also sound and will remain on during a rebuild. After the rebuild completes, an
alarm with a different tone will sound, signaling the completion of the build. This is a onetime
(non-repeating) tone.
The alarm can be disabled either in the BIOS Console or in the Web Console management utilities.
When disabled, the alarm will not sound unless it is re-enabled in one of the utilities.
The alarm can be silenced either in the BIOS Console or in the Web Console management utilities.
The default setting is enabled.
3.2 Intel
®
Raid Controller SRCU41L Characteristics
Table 4 shows the general characteristics for the Intel
®
Raid Controller SRCU41L.
The Intel
®
Raid Controller SRCU41L ensures data integrity by intelligently validating the
compatibility of the SCSI domain. The Intel
®
SRCU41L Raid Controller also uses Fusion-MPT
architecture that allows for thinner drivers and better performance.
3.3 Technical Specifications
The design and implementation of the Intel
®
Raid Controller SRCU41L minimizes
electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic
discharge. The Intel
®
SRCU41L Raid Controller carries the CE mark, C-Tick mark, FCC Self-
Certification logo, Canadian Compliance Statement, Korean MIC, Taiwan BSMI, and Japan VCCI,
and they meet the requirements of CISPR Class B.
Table 4. Intel
®
Raid Controller SRCU41L Characteristics
Flash
ROM
a
Serial
EEPROM
b
LVD/SE
Signaling
Ultra320 SCSI Data Transfers SCSI Features
SCSI
Termination
Yes Yes
16-bit SE
or LVD
interfaces
Up to 320 Mbytes/s as well as Fast,
Ultra, Ultra2, and Ultra160 speeds;
Synchronous offsets up to 62.
Plug n Play
Scatter/Gather
Activity LED
Active, Single
Ended, or LVD
a. For boot code and firmware
b. For BIOS configuration storage
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24

Comments to this Manuals

No comments