Page 1 - 1U Rack Mount Server

System Installation GuideGS-SR168 1U Rack Mount ServerIntel® Pentium Xeon Processor ServerboardRev. 100125A080-01680-F00

Page 2 - Table of Content

10GS-SR168 Rack Mount ServerSuper I/OController  ITE IT8712F-A Super I/OBuilt-in I/O  2 x Serial ports (COM, 1 at rear and 1 at front) 3 x USB 2.0

Page 3

11System OverviewChapter 2 System OverviewA. Chassis Cover F. HDD BlankB. Motehrboard - GA-9IVDPL G. CD-ROM DriveC. Fan Duct H. Back plane boardD. Sys

Page 4 - Network Options

12GS-SR168 Rack Mount ServerPlease observe the safety information in chapter “Important Safety Information”Do not expose the server to extreme enviro

Page 5

13Hardware Installation ProcessStep 3-2: CPU InstallationPlease make sure the CPU type and speed that are supported by the motherboard.Step 1Step 2St

Page 6

14GS-SR168 Rack Mount ServerStep 3-3: Heat Sink InstallationStep 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please wel

Page 7

15Hardware Installation ProcessStep 3-5: PCI Expansion Card InstallationGS-SR168 provides expansion riser slot for one PCI-X 64/66MHz slot; and one

Page 8 - WARNING!

16GS-SR168 Rack Mount ServerStep 3-6: Hard Disk Drive InstallationStep 1 Press the release button and pull the blank out of the drive bay.Step 2 Remov

Page 9 - Chapter 1 Features Summary

17Hardware Installation ProcessStep 3-7: FAN Duct Removal and InstallationStep 1 Pull up the screw-holder and lossen the thumbscrews. Lift up to remov

Page 10 - GS-SR168 Rack Mount Server

18GS-SR168 Rack Mount Server4-1: Front View of GS-SR168Chapter 4 Appearance of GS-SR168MOR-DCepyTmilSrotcennoCBSUsDEL)2MOCroF(54JRsDDHATASpa

Page 11 - Chapter 2 System Overview

System Appearance194-2: Rear View of GS-SR168rewoPtroPAGVtroPMOCtolSresiRrotcennoCdraobyeKrotcennoCesuoMsrotcennoCBSUstroP2&1NAL

Page 12 - Thumbscres

2GS-SR168 Rack Mount ServerTable of ContentSafety, Care and Regulatory Information...4Contents Packages .

Page 13 - Pin1 indicator

20GS-SR168 Rack Mount Server12671+12252614581ATX2BBAAASSEM:0SN4-3: Back Plane Borad Layout Introductionaibdcfeghjka)rotcennoCnaF(1FDb)rotcennoCnaF(2FD

Page 14 - Step 3-4: Memory Installation

21LED Description4-4: Switch and LED Indicators IntroductionPower/SleepNMILAN1/2 ActivitiesHDDStatusHDD Fail WarningIDNameStatusColor Condition Descri

Page 15 - Hardware Installation Process

22GS-SR168 Rack Mount Server4-5: LAN LED DescriptionColor Condition DescriptionGreen ON LAN Link / no AccessGreen BLINK LAN Access- OFF IdleYellow ON

Page 16 - Release button

23Connector Icon Description4-6 : Connector Icon DescriptionnocItsegguSnoitpircseDdraobyeKAGVesuoMNALtroPlaireSBSU

Page 17

24GS-SR168 Rack Mount ServerL12LAN1PCI-X_2JP15-1: GA-9IVDPL Motherboard LayoutChapter 5 Motherboard Layout & Jumper SettingABCEFGIHJKNLMFPOQRD A C

Page 18

25Jumper SettingL12LAN1PCI-X_2JP15-2: Jumper SettingCLR_CMOS ( (Clear CMOS Function)You may clear the CMOS data to its default values by this jumper.D

Page 19 - System Appearance

26GS-SR168 Rack Mount Server<Ç> Move to previous item<È> Move to next item<Å> Move to the item in the left hand<Æ> Move to the

Page 20

27BIOS Setupzzzzz MainThis setup page includes all the items in standard compatible BIOS.zzzzz AdvancedThis setup page includes all the items of AMI s

Page 21

28GS-SR168 Rack Mount Server System Time The time is calculated based on the 24-hour military time clock. Set the System Time (HH:MM:SS) Sys

Page 22 - 4-5: LAN LED Description

29BIOS Setup IDE Channel 0 Master, Slave / Channel 1 Master, Slave, Serial ATAThe category identifies the types of hard disk from drive C to F th

Page 23

3Table of ContentChapter 6 BIOS Setup ...26Main...

Page 24

30BIOS Setup System InformationThis category includes the information of Processor Type, Speed, Extended memory, BIOS Version,BIOS Date, System P

Page 25 - 5-2: Jumper Setting

31BIOS SetupFigure 2: AdvancedAdvancedAbout This Section: Advanced With this section, allowing user to configure your system for basic operation. User

Page 26 - Chapter 6 BIOS Setup

32GS-SR168 Rack Mount ServerPCI ConfigurationFigure 2-1: PCI ConfigurationEmbedded Video Controller Onboard VGA ControlEnabled Enable onboard V

Page 27

33BIOS SetupAdvanced Chipset ControlFigure 2-2: Advanced Chipset ControlUSB Controller This item allows users to enable or disable the USB device

Page 28

34GS-SR168 Rack Mount ServerForce Compliance ModeThis option allows user to function PCI-E Compliance mode by setting item to desired value.Ena

Page 29

35BIOS SetupAdvanced Processor OptionFigure 2-3: Advanced Processor OptionHyper Threading TechnologyEnabled Enables Hyper-Threading Technology F

Page 30 -  System Information

36GS-SR168 Rack Mount ServerPeripheral ConfigurationPhoenixBIOS Setup UtilityPeripheral Configuration Item Specific HelpSerial Port A [Enabled]Base I/

Page 31 - Advanced

37BIOS SetupSerial Port BThis allows users to configure serial prot B by using this option.Disabled Disable the configuration.Enabled Enable

Page 32 - PCI Configuration

38GS-SR168 Rack Mount ServerSerial ATAEnabled Enable Serial ATA device. (Default value)Disabled Disable the Serial ATA.Native Mode Operati

Page 33 - Advanced Chipset Control

39BIOS SetupReset Configuration DataYes Clear the Extended System Configuration Data (ESCD) area.No Disable this function. (default value)

Page 34

4GS-SR168 Rack Mount ServerSafety, Care and Regulatory Information Important safety informationRead and follow all instructions marked on the product

Page 35 - Advanced Processor Option

40GS-SR168 Rack Mount ServerHardware MonitorFigure 2-5: Hardware Monitor CPU 1&2/Backboard 1/2/3 TemperatureDisplay the current CPU1/2 tempe

Page 36 - Peripheral Configuration

41BIOS SetupSecurityFigure 3: Security***** About This Section: Security In this section, user can set either supervisor or user passwords, or bo

Page 37

42GS-SR168 Rack Mount ServerSet User PasswordYou can only enter but do not have the right to change the options of the setup menus. Whenyou selec

Page 38

43BIOS SetupServerFigure 4: ServerPhoenixBIOS Setup UtilityMain Advanced Security Server Boot ExitConsole Redirectio

Page 39

44GS-SR168 Rack Mount Server Com Port AddressIf this option is set to enabled, it will use a port on the motherboard.On-board COMA Use COMA as h

Page 40 - Hardware Monitor

45BIOS Setup Halt OnThe category determines whether the computer will stop if an error is detected during power up.NO Errors The system boot wil

Page 41 - Security

46GS-SR168 Rack Mount ServerBoot***** About This Section: Boot The “Boot” menu allows user to select among four possible types of boot devices li

Page 42

47BIOS SetupExitFigure 6: Exit***** About This Section: Exit Once you have changed all of the set values in the BIOS setup, you should save your

Page 43 - Console Redirection

48GS-SR168 Rack Mount ServerExit Saving ChangesThis option allows user to exit system setup with saving the changes.Press <Enter> on this i

Page 44

49BIOS SetupDiscard ChangesThis option allows user to load previos values from CMOS for all setup item.When you press <Enter> on this item,

Page 45

5Safety Information* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable i

Page 46

50GS-SR168 Rack Mount ServerAcronyms MeaningACPI Advanced Configuration and Power InterfaceAPM Advanced Power ManagementAGP Accelerated Graphics PortA

Page 47 - BIOS Setup

Appexdix51Acronyms MeaningI/O Input / OutputIOAPIC Input Output Advanced Programmable Input ControllerISA Industry Standard ArchitectureLAN Local Area

Page 49

6GS-SR168 Rack Mount ServerYour telephone company may make changes in its facilities, equipment, operations, or procedures thatcould affect proper ope

Page 50 - Chapter 7 Appendix

7Safety InformationNOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the totalload to be connected to a telephon

Page 51

8GS-SR168 Rack Mount Server; Chassis ; GA-9IVDPL Motherboard (Installed); Power Supply (Installed) ; GSMT User’s Manual; FAN Duct x 1 ; CPU Heat Sink

Page 52

9Feature SummaryMotherboard  GA-9IVDPLProcessor Supported  Dual socket 604 for Intel® Xeon(Nocona/Irwindale) processorsuopprts 3.6 GB and upper I